DocumentCode :
3236890
Title :
Measuring the parameters of a cage-rotor reluctance synchronous motor
Author :
Ferraz, C.A.M.D. ; de Souza, C.R.
Author_Institution :
Sch. of Electr. Eng., Salesian Center of Americana, Brazil
Volume :
2
fYear :
2001
fDate :
2001
Firstpage :
775
Abstract :
A three-phase two-pole line-start conventional rotor reluctance synchronous machine that comprises a cage was tested in the laboratory for the determination of its dynamic characteristics. The purpose is to obtain the machine equivalent circuit for synchronous and asynchronous operation modes. The vector diagram is the theoretical approach that is used in this work to get the synchronous performance modeling of the machine. Among other parameters with straightforward measurement procedures, the d-axis and q-axis machine reactance are required in the model. It is well known that the measurement of some parameters of cage-rotor machines may present some difficulty owing to the distortion that is introduced by the cage. The q-axis is one of these critical parameters to be measured. The question is how to obtain accurate parameter values from measurements if a damper or a cage is present. In this work the d-axis reactance was obtained via the conventional no-load test. As for the determination of the q-axis reactance, the steady-state no-load and load tests devised by V.B. Honsinger (1971) were applied. The variation of some parameters with the frequency was obtained by feeding the machine with an inverter. Different stator voltages were applied as well. The torque-speed curves of the machine were also obtained. The setup details a list of the measured parameters and other results are presented in the paper
Keywords :
electric reactance measurement; electric resistance measurement; equivalent circuits; machine testing; reluctance motors; rotors; stators; asynchronous operation; cage-rotor machines; cage-rotor reluctance synchronous motor; d-axis machine reactance; damper; dynamic characteristics; inverter fed machine; leakage reactance measurement; machine equivalent circuit; no-load test; parameters measurement; q-axis machine reactance; stator voltages; steady-state load test; steady-state no-load test; synchronous operation; three-phase two-pole line-start; torque-speed curves; vector diagram; winding resistance measurement; Circuit testing; Distortion measurement; Equivalent circuits; Frequency; Inverters; Laboratories; Stators; Steady-state; Synchronous machines; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical and Computer Engineering, 2001. Canadian Conference on
Conference_Location :
Toronto, Ont.
ISSN :
0840-7789
Print_ISBN :
0-7803-6715-4
Type :
conf
DOI :
10.1109/CCECE.2001.933540
Filename :
933540
Link To Document :
بازگشت