DocumentCode :
3237251
Title :
Technical requirements and development of FRP prestressed tendons anchorage
Author :
Li, Fang-yuan ; Chen, Xing-bo ; Zhang, Yu
Author_Institution :
Dept. of Bridge Eng., Tongji Univ., Shanghai, China
fYear :
2011
fDate :
22-24 April 2011
Firstpage :
5579
Lastpage :
5582
Abstract :
For the application of FRP for prestress should have the specially anchorage system, after introduced different anchorage of many countries, the key points for FRP anchorage were introduced especially for the lateral stress limitation and the measures to reduce the lateral stress were presented. When get the total anchorage force, reducing the high lateral stress to an average level is the best way to avoid breaking FRP, which can been referred for the application and research of FRP tendons.
Keywords :
bridges (structures); polymers; FRP prestressed tendons anchorage; fiber reinforced polymer; technical requirements; Bridges; Carbon; Concrete; Polymers; Steel; Stress; Tendons; anchorage; fiber reinforced polymer; lateral stress; prestress; technical requirements;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electric Technology and Civil Engineering (ICETCE), 2011 International Conference on
Conference_Location :
Lushan
Print_ISBN :
978-1-4577-0289-1
Type :
conf
DOI :
10.1109/ICETCE.2011.5775287
Filename :
5775287
Link To Document :