DocumentCode :
3237653
Title :
RITS-3 self-break water switch maintenance
Author :
Puetz, E. ; Portillo, S. ; Hahn, K. ; Molina, I. ; Cordova, S. ; Maenchen, J. ; Johnson, D.L. ; Gignac, R. ; Wilkins, F.
Author_Institution :
Sandia Nat. Lab., Albuquerque, NM, USA
fYear :
2004
fDate :
23-26 May 2004
Firstpage :
421
Lastpage :
423
Abstract :
The radiographic integrated test stand (RITS-3) is a 5-MV, 160-kA, 70-ns inductive voltage adder accelerator at Sandia National Laboratories used to develop critical understanding of x-ray sources and flash radiographic drivers. On RITS-3 three pulse forming lines (PFLs) are used to drive three inductive voltage adder cavities. Each PFL contains a fast-pulse-charged, self-breakdown annular water switch that is used for initial pulse shaping and timing. Low loss in the switches combined with good synchronization is required for efficient operation of the accelerator. Switch maintenance is closely monitored over time to determine the effects of wear on switch breakdown performance.
Keywords :
maintenance engineering; pulse shaping; pulsed power switches; radiography; 160 kA; 5 MV; 70 ns; Sandia National Laboratories; annular water switch; fast-pulse-charged water switch; flash radiographic drivers; inductive voltage adder accelerator; inductive voltage adder cavities; pulse forming lines; radiographic integrated test stand; self-break water switch maintenance; switch breakdown performance; synchronization; x-ray sources; Electric breakdown; Laboratories; Life estimation; Monitoring; Pulse shaping methods; Radiography; Switches; Testing; Timing; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Modulator Symposium, 2004 and 2004 High-Voltage Workshop. Conference Record of the Twenty-Sixth International
Print_ISBN :
0-7803-8586-1
Type :
conf
DOI :
10.1109/MODSYM.2004.1433602
Filename :
1433602
Link To Document :
بازگشت