DocumentCode
3241257
Title
Destructive Test Facility Relies on VXI Fiber Optic Network for Synchronous Data Acquisition
Author
Faubert, Nicole ; Kelm, Louis ; Krebs, Steven C.
Author_Institution
DynamicSignals LLC, Lockport, IL
fYear
2006
fDate
18-21 Sept. 2006
Firstpage
4
Lastpage
7
Abstract
VXIbus is an ideal standard for instrumentation associated with developmental test systems used by industrial applications due to its adaptability, accuracy, and responsiveness. This application note is one such example of a VXI solution for a worldwide leader in commercial property and risk management that operates a destructive test facility to analyze the results of disasters predominantly caused by fire. The company implemented a re-configurable 2,400 channel test system based on KineticSystems´ VXI modules that used a fiber optic ring to synchronize multiple chassis and multiple channels. Technical details of the VXI implementation and results will be discussed.
Keywords
data acquisition; optical fibre networks; peripheral interfaces; test facilities; VXI fiber optic network; destructive test facility; synchronous data acquisition; Data acquisition; Delay; Fires; Instruments; Optical fiber networks; Risk analysis; Risk management; Standards development; System testing; Test facilities;
fLanguage
English
Publisher
ieee
Conference_Titel
Autotestcon, 2006 IEEE
Conference_Location
Anaheim, CA
ISSN
1088-7725
Print_ISBN
1-4244-0051-1
Electronic_ISBN
1088-7725
Type
conf
DOI
10.1109/AUTEST.2006.283594
Filename
4062323
Link To Document