Abstract :
The accuracy of harmonic currents detector and characteristics of current controls are important to improve the compensation characteristics of an active power filter. This paper proposes a detector which has high accuracy and good response by applying pq-theory and moving average high-pass-filter (HPF) and good response current control by applying current-deviation code-distinction. A new modified detection system using a moving average HPF whose sampling time is changed according to the source frequency fluctuation is also proposed. The active power filter combining the proposed method of the detector and the current control can compensate harmonic currents which are generated by a three-phase rectifier with a DC filter capacitor with high accuracy and good response
Keywords :
active filters; compensation; electric current control; electric current measurement; harmonics; high-pass filters; power filters; DC filter capacitor; active power filter; compensation characteristics; current control; current detection; current-deviation code-distinction; harmonic currents detector; high accuracy; high-pass-filter; pq-theory; sampling time; source frequency fluctuation; Active filters; Current control; DC generators; Detectors; Fluctuations; Frequency; Power generation; Power harmonic filters; Power system harmonics; Sampling methods;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics Specialists Conference, 1998. PESC 98 Record. 29th Annual IEEE
Conference_Location :
Fukuoka
ISSN :
0275-9306
Print_ISBN :
0-7803-4489-8
Type :
conf
DOI :
10.1109/PESC.1998.701906
Filename :
701906
Link To Document :
بازگشت