  • Abstract
    A pre aeration-SBR process was adopted in the treatment of sewage wastewater in Qingdao City. The amount of wastewater was 500t/d, with COD of 500.0mg/L, BOD5 of 235.8 mg/L, SS of 165.8 mg/L and NH4+-N of 60.5 mg/L on average. The average removal rates of these indexes are 92.3%, 95.6%, 92.8% and 86.0% respectively. The effluent concentrations of these indexes are 38.3 mg/L, 10.3 mg/L, 12.0 mg/L and 8.5 mg/L, which met the grade first B requirements of Discharge standard of pollutants for municipal wastewater treatment plant (GB18918- 2002). The cost was 0.57 Yuan per ton of wastewater. This process had the advantages of low land area, low cost, high effect and simple operation and so on.
  • Keywords
    chemical engineering; chemical reactors; sewage treatment; wastewater treatment; Qingdao City; municipal wastewater treatment plant; pollutants discharge standard; preaeration-SBR process; sequencing batch reactors; sewage wastewater treatment; Cities and towns; Effluents; Microorganisms; Nitrogen; Wastewater; Wastewater treatment; Water pollution; Balance with pre-aeration; SBR; Sewage wastewater;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electric Technology and Civil Engineering (ICETCE), 2011 International Conference on
  • Conference_Location
    Lushan
  • Print_ISBN
    978-1-4577-0289-1
  • Type

    conf

  • DOI
    10.1109/ICETCE.2011.5775781
  • Filename
    5775781