• DocumentCode
    3255692
  • Title

    Research on the Failure Diagnostics Parameters and the Reliability Prediction Model of the Electrical Contacts

  • Author

    Fang Yao ; Jianguo Lu ; Zheng, Jianrong ; Huang, Zhangwu

  • Author_Institution
    Inst. of Electr. Apparatus, Hebei Univ. of Technol., Tianjin
  • fYear
    2006
  • fDate
    25-27 Sept. 2006
  • Firstpage
    69
  • Lastpage
    72
  • Abstract
    The dynamic contact voltage of electromagnetic relays are measured in the paper. Both its statistics characteristic and its time sequence characteristic are studied in detail. Based on these characteristics, the failure diagnostics parameters are determined in the light of principle factor method and the failure prediction model of the electrical contact and are set up in accordance with the time sequence prediction and fuzzy method. By the model, the characteristic parameters of the contact failure can be predicted as can the contact reliability of the relay.
  • Keywords
    electrical contacts; failure analysis; relays; reliability; dynamic contact voltage; electrical contacts; electromagnetic relays; failure diagnostics parameters; failure prediction model; fuzzy method; reliability prediction model; time sequence prediction; Communications technology; Contact resistance; Electric variables measurement; Electrical resistance measurement; Electromagnetic measurements; Hardware; Predictive models; Relays; Telephony; Testing; contact resistance; distribution density; prediction model fuzzy logic; time sequence;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical contacts - 2006, proceedings of the fifty-second ieee holm conference on
  • Conference_Location
    Montreal, QC
  • Print_ISBN
    1-4244-0581-5
  • Type

    conf

  • DOI
    10.1109/HOLM.2006.284067
  • Filename
    4063103