• DocumentCode
    3259977
  • Title

    Silicate contamination on ceramic IC packages and its effect on lid adhesion properties

  • Author

    Chin, B. ; Lim, K. ; Chong, Y.C.

  • Author_Institution
    Integrated Circuits Bus. Div., Hewlett-Packard, Singapore
  • fYear
    1995
  • fDate
    27 Nov-1 Dec 1995
  • Firstpage
    221
  • Lastpage
    224
  • Abstract
    This paper presents a case history of a packaging failure that was caused by contamination introduced in one of the processes on the assembly line. Results of the failure analysis via the use of the X-Ray Photoelectron Spectroscopy (XPS) for contamination at various stages of the Ceramic Pin Grid Array (CPGA) packaging assembly process, and an analysis of the contact angles obtained from the ceramic substrate surface to indicate wettability are presented
  • Keywords
    X-ray photoelectron spectra; adhesion; ceramics; contact angle; failure analysis; hybrid integrated circuits; impurities; integrated circuit packaging; integrated circuit reliability; wetting; XPS; ceramic IC packages; ceramic pin grid array packaging assembly process; ceramic substrate surface; contact angles; lid adhesion properties; packaging failure; silicate contamination; wettability; Adhesives; Assembly; Ceramics; Contamination; Grain size; History; Integrated circuit packaging; Rough surfaces; Surface roughness; Temperature;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Physical and Failure Analysis of Integrated Circuits, 1995., Proceedings of the 1995 5th International Symposium on the
  • Print_ISBN
    0-7803-2797-7
  • Type

    conf

  • DOI
    10.1109/IPFA.1995.487627
  • Filename
    487627