DocumentCode
3259977
Title
Silicate contamination on ceramic IC packages and its effect on lid adhesion properties
Author
Chin, B. ; Lim, K. ; Chong, Y.C.
Author_Institution
Integrated Circuits Bus. Div., Hewlett-Packard, Singapore
fYear
1995
fDate
27 Nov-1 Dec 1995
Firstpage
221
Lastpage
224
Abstract
This paper presents a case history of a packaging failure that was caused by contamination introduced in one of the processes on the assembly line. Results of the failure analysis via the use of the X-Ray Photoelectron Spectroscopy (XPS) for contamination at various stages of the Ceramic Pin Grid Array (CPGA) packaging assembly process, and an analysis of the contact angles obtained from the ceramic substrate surface to indicate wettability are presented
Keywords
X-ray photoelectron spectra; adhesion; ceramics; contact angle; failure analysis; hybrid integrated circuits; impurities; integrated circuit packaging; integrated circuit reliability; wetting; XPS; ceramic IC packages; ceramic pin grid array packaging assembly process; ceramic substrate surface; contact angles; lid adhesion properties; packaging failure; silicate contamination; wettability; Adhesives; Assembly; Ceramics; Contamination; Grain size; History; Integrated circuit packaging; Rough surfaces; Surface roughness; Temperature;
fLanguage
English
Publisher
ieee
Conference_Titel
Physical and Failure Analysis of Integrated Circuits, 1995., Proceedings of the 1995 5th International Symposium on the