• DocumentCode
    3260708
  • Title

    Condition assessment of oil-paper insulation in large power equipments using transfer function zero of debye model

  • Author

    Baral, A. ; Chakravorti, S.

  • Author_Institution
    Electrical Engineering Department, Jadavpur University Kolkata, West Bengal, India
  • fYear
    2013
  • fDate
    6-8 Dec. 2013
  • Firstpage
    145
  • Lastpage
    149
  • Abstract
    Use of Debye Model to analyze insulation response, recorded from high voltage power equipments, is common among researchers. Available literature shows that relaxation characteristics of dipoles present in oil and paper have different relaxation times. This implies oil and paper condition influence separate branches in Debye Model. In the present work a new aging sensitive performance parameter is introduced. The parameter can be evaluated from Transfer Function, TFD(S) of Debye Model. The performance parameter mentioned above is one of the zeros (Z1) of TFD(s).T he capability of Z1 as an insulation condition sensitive parameter is tested on samples constructed in the laboratory.
  • Keywords
    IEEE Xplore; Portable document format; Aging; Debye Model; Oil-paper insulation; Transfer Function; Zero; tanδ;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Condition Assessment Techniques in Electrical Systems (CATCON), 2013 IEEE 1st International Conference on
  • Conference_Location
    Kolkata
  • Print_ISBN
    978-1-4799-0081-7
  • Type

    conf

  • DOI
    10.1109/CATCON.2013.6737488
  • Filename
    6737488