DocumentCode :
3260969
Title :
Influence of LV neutral grounding on global Earthing Systems
Author :
Cafaro, G. ; Montegiglio, P. ; Torelli, F. ; Barresi, A. ; Colella, P. ; De Simone, A. ; Di Silvestre, M.L. ; Martirano, L. ; Morozova, E. ; Napoli, R. ; Parise, G. ; Parise, L. ; Pons, E. ; Riva Sanseverino, E. ; Tommasini, R. ; Tummolillo, F. ; Valtorta
Author_Institution :
Dipt. di Ing. Elettr. e dell´Inf., Politec. di Bari, Bari, Italy
fYear :
2015
fDate :
10-13 June 2015
Firstpage :
389
Lastpage :
394
Abstract :
International Standards define a Global Earthing System as an earthing net created interconnecting local Earthing Systems (generally through the shield of MV cables and/or bare buried conductors). In Italy the Regulatory Authority for Electricity and Gas requires Distributors to guarantee the electrical continuity of LV neutral conductor. This requirement has led to the standard practice of realizing “reinforcement groundings” along the LV neutral conductor path and at users´ delivery cabinet. Moreover, in urban high load scenarios (prime candidates to be part of a Global Earthing System), it is common that LV distribution scheme creates, through neutral conductors, an effective connection between grounding systems of MV/LV substations, modifying Global Earthing System consistency. Aim of this paper is to evaluate the effect, in terms of electrical safety, of the above mentioned LV neutral distribution scheme when an MV-side fault to ground occurs. At this purpose simulations are carried out on a realistic urban test case and suitable evaluation indexes are proposed.
Keywords :
conductors (electric); earthing; power cables; substations; LV distribution scheme; LV neutral conductor; LV neutral grounding; MV cable shield; MV-LV substations; MV-side fault; bare buried conductors; electrical continuity; electrical safety; global earthing systems; grounding systems; interconnecting local earthing eystems; international standards; reinforcement groundings; urban high load scenarios; users delivery cabinet; Conductors; Electric potential; Electrodes; Fault currents; Grounding; Soil; Substations; GES; GGS; Global Earting System; Global Grounding System; Ground potential; LV neutral conductor; Maxwell Sub-areas Method;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Environment and Electrical Engineering (EEEIC), 2015 IEEE 15th International Conference on
Conference_Location :
Rome
Print_ISBN :
978-1-4799-7992-9
Type :
conf
DOI :
10.1109/EEEIC.2015.7165193
Filename :
7165193
Link To Document :
بازگشت