DocumentCode
3263286
Title
A reliability analysis of failsoft FDDI networks
Author
Yin, Jiahnsheng ; Silio, Charles B., Jr.
Author_Institution
Dept. of Eng., Maryland Univ., College Park, MD, USA
fYear
1992
fDate
13-16 Sep 1992
Firstpage
158
Lastpage
167
Abstract
The reliability of three fiber distributed data interface (FDDI) network topologies is examined. The three interconnection topologies considered are a tree, a double ring, and a ring of trees. The reliability measure is terminal-pair reliability in which the probability P [h (s ,t )] that two arbitrarily positioned terminal stations (s and t ) can communicate with each other is calculated. For the three FDDI network topologies considered, closed-form expressions are obtained for worst-case reliability as a function of the stations´ positions. The expressions are used to optimize the number of ports in and the topological interconnections of the wiring concentrators in order to achieve highest reliability for a given number of stations
Keywords
FDDI; local area networks; network topology; reliability; trees (mathematics); closed-form expressions; double ring; failsoft FDDI networks; fiber distributed data interface; interconnection topologies; network topologies; ports; reliability analysis; ring of trees; terminal stations; terminal-pair reliability; topological interconnections; tree; trees ring; wiring concentrators; worst-case reliability; Availability; Degradation; FDDI; Failure analysis; Fault tolerance; Military aircraft; Network topology; Position measurement; Probability; Telecommunication network reliability;
fLanguage
English
Publisher
ieee
Conference_Titel
Local Computer Networks, 1992. Proceedings., 17th Conference on
Conference_Location
Minneapolis, MN
Print_ISBN
0-8186-3095-7
Type
conf
DOI
10.1109/LCN.1992.228162
Filename
228162