Title :
Direct measurement of switch-mode pulse modulation
Author_Institution :
Tektronix Inc., Beaverton, OR, USA
Abstract :
A digitally precise time-interval to voltage converter (TVC) is described. The TVC converts timing variants to voltage variations. Since measurements are available pulse-by-pulse without interruption, a TVC can reliably isolate intermittent timing faults. Since the output signal is available in real time, a TVC makes possible the correlation of timing modulations with voltage and current waveforms. The TVC offers a direct method of viewing and measuring pulse modulation dynamics that bypasses the cumbersome and indirect techniques currently in use. This leads to more efficient troubleshooting and more thorough design verification of switch-mode converters
Keywords :
power convertors; pulse modulation; switched mode power supplies; TVC; intermittent timing faults; pulse modulation dynamics; pulse modulation measurement; switch-mode converters; switch-mode pulse modulation; time-interval to voltage converter; timing variants; voltage variations; Counting circuits; Digital modulation; Oscilloscopes; Pulse measurements; Pulse modulation; Pulse width modulation; Signal processing algorithms; Space vector pulse width modulation; Timing; Voltage;
Conference_Titel :
Applied Power Electronics Conference and Exposition, 1992. APEC '92. Conference Proceedings 1992., Seventh Annual
Conference_Location :
Boston, MA
Print_ISBN :
0-7803-0485-3
DOI :
10.1109/APEC.1992.228433