• DocumentCode
    3268180
  • Title

    Evaluation of the grounding circuit measurements for stator ground-fault location of synchronous generators

  • Author

    Blanquez, Francisco R. ; Rebollo, Emilio ; Platero, Carlos A.

  • Author_Institution
    Electr. Eng. Dept., Polytech. Univ. of Madrid, Madrid, Spain
  • fYear
    2013
  • fDate
    1-3 Nov. 2013
  • Firstpage
    229
  • Lastpage
    233
  • Abstract
    Locating stator-winding ground faults accurately is a very difficult task. In this paper the grounding circuit measurements are evaluated in order to obtain information about the stator ground-fault location in synchronous generators. In power generators grounded through a high impedance, the relation between the neutral voltage and the phase voltage provide a first estimation of the fault location. The location error by using this ratio depends on the fault resistance and the value of the capacitance to ground of the stator winding. However, the error added by ignoring the value of the fault resistance is the most relevant term. This location estimation and the location error have been evaluated through the data of a real synchronous machine.
  • Keywords
    capacitance; earthing; electric resistance; fault location; stators; synchronous generators; capacitance; fault location error; fault resistance; grounding circuit measurements; neutral voltage; phase voltage; power generator; stator winding ground fault location estimation; synchronous generator; synchronous machine; Circuit faults; Estimation; Grounding; Radio frequency; Resistance; Stator windings; Stator ground fault; fault location; generator protection;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Environment and Electrical Engineering (EEEIC), 2013 13th International Conference on
  • Conference_Location
    Wroclaw
  • Print_ISBN
    978-1-4799-2802-6
  • Type

    conf

  • DOI
    10.1109/EEEIC-2.2013.6737913
  • Filename
    6737913