Abstract :
The electrical and mechanical design of drive components must suit wiring practices based on recognized industry standards. Safety grounding, medium voltage cable termination, cable training, and electrical clearances are involved. Design shortcomings found during installation of several large 4 kV drives are discussed, together with the corrective actions taken (including the revision of specifications for later drive projects)
Keywords :
earthing; electric connectors; power cables; safety; variable speed drives; 4 kV; adjustable speed drives safety grounding; cable training; electrical clearances; electrical design; mechanical design; medium voltage cable termination; wiring practices; Electronics cooling; Frequency; Grounding; Inductors; Inverters; Medium voltage; Power cables; Power generation; Synchronous motors; Variable speed drives;