Title :
Design of Gyrotron FU CW VI for 600 MHz DNP-NMR experiment
Author :
Glyavin, M. ; Idehara, T. ; Khizhnyak, V. ; Luchinin, A. ; Manuilov, V. ; LaAgusu ; Ogawa, I. ; Saito, T. ; Takahashi, H. ; Fujiwara, T.
Author_Institution :
Inst. of Appl. Phys., Russian Acad. of Sci., Nizhny Novgorod
Abstract :
For the application of gyrotron to accurate measurement of DNP-NMR, frequency continuous tunability is desired in 2 GHz range at least. The demountable Gyrotron FU CW VI tube based on 15 T helium free superconducting magnet are under development. The gyrotron operation is in CW mode at the fundamental cyclotron harmonic. The output power is 100 W in the whole frequency tunable range and the center frequency is 394.6 GHz. The gyrotron will be applied to 600 MHz DNP-NMR experiments.
Keywords :
gyrotrons; DNP-NMR experiment; Gyrotron FU CW VI; frequency continuous tunability; fundamental cyclotron harmonic; helium free superconducting magnet; magnetic flux density 15 T; Coaxial components; Conductors; Eigenvalues and eigenfunctions; Frequency; Gyrotrons; Impedance; Magnetic fields; Nuclear magnetic resonance; Physics; Tuning;
Conference_Titel :
Infrared, Millimeter and Terahertz Waves, 2008. IRMMW-THz 2008. 33rd International Conference on
Conference_Location :
Pasadena, CA
Print_ISBN :
978-1-4244-2119-0
Electronic_ISBN :
978-1-4244-2120-6
DOI :
10.1109/ICIMW.2008.4665547