DocumentCode
3284527
Title
Measurement of thermal parameters for mineral oil with transient method
Author
Gu Yaxiong ; Zhao Zimin
Author_Institution
Sch. of Electr. Inf., Southwest Pet. Univ., Chengdu, China
fYear
2011
fDate
15-17 April 2011
Firstpage
1453
Lastpage
1455
Abstract
Thermal physical parameters such as specific heat and heat diffusion coefficient were definitely obtained with transient method in which surface temperature variation of a thin Pt wire within a transient period was measured and the measured results were imitated by least square principle. Effectiveness of the method was certified in the case of glycerin. While the method was applied to mineral oil VG46, it was found that there was very weak temperature dependence of thermal parameters for mineral oil VG46 at normal temperature.
Keywords
heat transfer; least squares approximations; minerals; oils; platinum; transient analysis; wires; Pt; glycerin; heat diffusion coefficient; least square principle; mineral oil VG46; thermal parameter measurement; thin platinum wire; transient method; Equations; Heating; Mathematical model; Minerals; Temperature measurement; Transient analysis; Wires; least square principle; mineral oil; thermal parameter; transient method;
fLanguage
English
Publisher
ieee
Conference_Titel
Electric Information and Control Engineering (ICEICE), 2011 International Conference on
Conference_Location
Wuhan
Print_ISBN
978-1-4244-8036-4
Type
conf
DOI
10.1109/ICEICE.2011.5777820
Filename
5777820