• DocumentCode
    3288145
  • Title

    Common-source TLD and RADFET characterization of Co-60, Cs-137, and X-ray irradiation sources [bipolar linear ICs]

  • Author

    Simons, M. ; Pease, R.L. ; Fleetwood, D.M. ; Schwa, J.R. ; Krzesniak, M.F. ; Turflinger, T.L. ; Buaron, J. ; Riewe, L.C. ; Kemp, W.T. ; Duggan, P.W.C. ; Johnston, A.H. ; Wiedeman, M.C. ; Mills, R.E. ; Holmes-Siedle, A.G. ; Cohn, L.M. ; Doane, H.J. ; Lohme

  • Author_Institution
    Res. Triangle Inst., Research Triangle Park, NC, USA
  • fYear
    1997
  • fDate
    35635
  • Firstpage
    28
  • Lastpage
    34
  • Abstract
    Dose rate and dose enhancement (DE) factors were measured at fifteen gamma sources at eight different laboratories using thermoluminescent dosimeters (TLDs) from two independent sources and pMOS RADFETs, respectively. Dose enhancement factors were determined by comparing the responses of RADFETs with ceramic and gold-flashed kovar lids. Dose enhancement factors measured within Pb/Al test enclosures varied from essentially 1.0 (no enhancement) very close to a Co-60 room or tunnel source up to 1.24 within an enclosed Gammacell 220. DE factors between 1.5 and 1.8 were measured within a Pb/Al box behind a 2-inch Pb brick attenuator in a Co-60 room source. Two Cs-137 sources evaluated were characterized by DE factors extending from 1.17 up to 1.3-1.4 inside the Pb/Al box. Gamma cell dose rates determined from TLDs from the Naval Surface Warfare Center (NSWC)-Crane and Sandia National Laboratories (SNL) were generally close to expected levels. Dose rates were measured in an ARACOR 4100 X-ray source using both SNL dual-dielectric RADFETs and Radiation Experiments and Monitors (REM) thick thermal oxide RADFETs
  • Keywords
    X-ray effects; bipolar analogue integrated circuits; gamma-ray effects; integrated circuit testing; thermoluminescent dosimeters; ARACOR 4100 X-ray source; Co; Cs; Naval Surface Warfare Center; Sandia National Laboratories; X-ray irradiation sources; bipolar linear ICs; brick attenuator; dose enhancement; gamma cell dose rates; pMOS RADFETs; thermoluminescent dosimeters; thick thermal oxide; tunnel source; Attenuators; Calibration; Cranes; Electromagnetic scattering; Electronic warfare; Ionization chambers; Laboratories; Particle scattering; Semiconductor device testing; Weapons;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Radiation Effects Data Workshop, 1997 IEEE
  • Conference_Location
    Snowmass Village, CO
  • Print_ISBN
    0-7803-4061-2
  • Type

    conf

  • DOI
    10.1109/REDW.1997.629793
  • Filename
    629793