• DocumentCode
    3288430
  • Title

    Design, fabrication and testing of a large anti-scatter grid for megavolt /spl gamma/-ray imaging

  • Author

    Watson, S.A. ; Appleby, M. ; Klinger, J. ; Balzer, S. ; Lebeda, C. ; Bowman, D. ; Montoya, J. ; Bultman, D. ; Vecere, C. ; Gossein, C.

  • Author_Institution
    Los Alamos Nat. Lab., NM
  • Volume
    2
  • fYear
    2005
  • fDate
    23-29 Oct. 2005
  • Firstpage
    717
  • Lastpage
    721
  • Abstract
    Despite a century-old patent, and wide application at lower energies, the fabrication of thick anti-scatter "Bucky" grids for application at megavolt energies has been an elusive goal. We discuss the design, fabrication and testing of a 45 cm-diameter grid with a focal length of 525 cm for use at the 20 MeV DARHT flash radiography facility. The predominant difficulties overcome were: (1) understanding the performance of such grids prior to fabrication, and (2) the precision fabrication itself. To understand the former, we employed a specially modified version of the MCNP Monte Carlo code run on the ASC blue-mountain supercomputer at Los Alamos to explore and optimize the parameter space. These calculations were benchmarked at the Los Alamos microtron facility using a small prototype grid. To have useful scatter rejection at megavolt energies, grid ratios of several hundred-to-one are required. State-of-the-art grids used in medical radiography have grid ratios of ten-to-one. We demonstrate a unique casting technology capable of accurately manufacturing large grids with very high grid ratios. Promising initial test results are also presented. It is our belief that similar grids will prove useful in a wide range of potential applications including: megavolt NDE radiography, Compton scatter radiography, balloon-born gamma-ray astronomy, medical therapy, and in the intended application of flash radiography at Los Alamos\´ DARHT facility
  • Keywords
    Monte Carlo methods; gamma-ray apparatus; radiography; ASC blue-mountain supercomputer; Compton scatter radiography; DARHT flash radiographic facility; antiscatter Bucky grids; balloon-born gamma-ray astronomy; casting technology; flash radiography; grid ratios; large antiscatter grid; medical radiography; medical therapy; megavolt NDE radiography; megavolt gamma-ray imaging; modified MCNP Monte Carlo code; Biomedical imaging; Fabrication; Monte Carlo methods; Optical imaging; Prototypes; Radiography; Scattering; Space technology; Supercomputers; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2005 IEEE
  • Conference_Location
    Fajardo
  • ISSN
    1095-7863
  • Print_ISBN
    0-7803-9221-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2005.1596358
  • Filename
    1596358