• DocumentCode
    3288532
  • Title

    Investigation of performance degradation for TNB newly commissioned combined cycle power plant Case study at PD1, Tuanku Jaafar Power Station, Port Dickson

  • Author

    Lee, C.H. ; Mamat, Zainul Asri

  • Author_Institution
    Power Plant Optimization Group, TNB Res. Sdn. Bhd., Bangi, Malaysia
  • fYear
    2009
  • fDate
    7-8 Dec. 2009
  • Firstpage
    124
  • Lastpage
    128
  • Abstract
    Phase 1 of Tuanku Jaafar Power Station, Port Dickson (PD1) is one of the newest power plants in Tenaga Nasional Berhad (TNB). This combined cycle plant with the nominal capacity of 750 MW started its commercial operation in 2005. However, in less than 2 years of its operation, the plant has indicated significant capacity degradation. Consequently, TNB carried few investigations to determine the cause for the capacity degradation. This paper describes the approach taken and the outcomes of the investigations.
  • Keywords
    combined cycle power stations; performance evaluation; power generation reliability; Port Dickson; TNB; Tenaga Nasional Berhad power plant; Tuanku Jaafar Power Station; capacity degradation; combined cycle power plant; performance degradation; power 750 MW; Asset management; Atmospheric modeling; Blades; Combustion; Degradation; Group technology; Power generation; Testing; Thermodynamics; Turbines; non-recoverable degradation; performance degradation; thermodynamic modeling;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Energy and Environment, 2009. ICEE 2009. 3rd International Conference on
  • Conference_Location
    Malacca
  • Print_ISBN
    978-1-4244-5144-9
  • Electronic_ISBN
    978-1-4244-5145-6
  • Type

    conf

  • DOI
    10.1109/ICEENVIRON.2009.5398657
  • Filename
    5398657