DocumentCode
3288619
Title
Radiation hard bulk CMOS ROM dose rate upset: detailed analysis technique and results
Author
Nikiforov, Alexander Y. ; Guminov, Vladimir N. ; Telets, Vitally A.
Author_Institution
Specialized Electron. Syst., Moscow, Russia
fYear
1997
fDate
35635
Firstpage
44
Lastpage
47
Abstract
The detailed dose rate effects investigation of a Radiation Hard Bulk Complementary Metal-Oxide-Semiconductor Read Only Memory (CMOS ROM) family is performed with the “RADON-5E” pulsed laser simulator. The low-impedance probe technique is used to measure transient responses along the information path inside the chip. It is found that the ROM dose rate upset level is determined by the preamplifier´s upset level. The essential dependence of ROM upset duration on the operational frequency is obtained and analyzed
Keywords
CMOS memory circuits; failure analysis; integrated circuit reliability; integrated circuit testing; laser beam effects; radiation hardening (electronics); read-only storage; transient analysis; transient response; RADON-5E; ROM upset duration; dose rate effects; dose rate upset; low-impedance probe technique; operational frequency dependence; preamplifier upset level; pulsed laser simulator; radiation hard bulk CMOS ROM; transient response measurement; Analytical models; CMOS integrated circuits; Integrated circuit testing; Laser beams; Probes; Pulse amplifiers; Read only memory; Semiconductor device measurement; Semiconductor lasers; X-ray lasers;
fLanguage
English
Publisher
ieee
Conference_Titel
Radiation Effects Data Workshop, 1997 IEEE
Conference_Location
Snowmass Village, CO
Print_ISBN
0-7803-4061-2
Type
conf
DOI
10.1109/REDW.1997.629796
Filename
629796
Link To Document