DocumentCode :
3288720
Title :
Design of gas flow meter calibration based on sonic nozzles using negative pressure method
Author :
Zheng, Huifeng ; Ge, Yingqi ; Mao, Qianmin
Author_Institution :
Coll. of Metrol. & Meas. Eng., China Jiliang Univ., Hangzhou, China
fYear :
2011
fDate :
15-17 April 2011
Firstpage :
3175
Lastpage :
3178
Abstract :
In order to improve the accuracy and efficiency of gas flow meter calibration, the auto gas meter calibration system using the negative pressure method based on automatic sonic nozzle was developed. Firstly the calibration principle of the sonic nozzle was analyzed, which is the base of the calibration. Then the overall system design and performance were given and the key issues and its solutions were discussed. Finally, the experimental data were acquired and analyzed. The calibration system which has been put into use in meter factory was proved to be automatic, high ability of anti-interference, exact, efficient and reliable during the applications.
Keywords :
calibration; flowmeters; nozzles; automatic sonic nozzle; gas flow meter calibration; negative pressure method; Calibration; Educational institutions; Electronic mail; Fluid flow; Fluid flow measurement; Metrology; Pressure measurement; Auto Calibration; Gas flow meter; Negative pressure method; Sonic Nozzle;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electric Information and Control Engineering (ICEICE), 2011 International Conference on
Conference_Location :
Wuhan
Print_ISBN :
978-1-4244-8036-4
Type :
conf
DOI :
10.1109/ICEICE.2011.5778057
Filename :
5778057
Link To Document :
بازگشت