DocumentCode
3288720
Title
Design of gas flow meter calibration based on sonic nozzles using negative pressure method
Author
Zheng, Huifeng ; Ge, Yingqi ; Mao, Qianmin
Author_Institution
Coll. of Metrol. & Meas. Eng., China Jiliang Univ., Hangzhou, China
fYear
2011
fDate
15-17 April 2011
Firstpage
3175
Lastpage
3178
Abstract
In order to improve the accuracy and efficiency of gas flow meter calibration, the auto gas meter calibration system using the negative pressure method based on automatic sonic nozzle was developed. Firstly the calibration principle of the sonic nozzle was analyzed, which is the base of the calibration. Then the overall system design and performance were given and the key issues and its solutions were discussed. Finally, the experimental data were acquired and analyzed. The calibration system which has been put into use in meter factory was proved to be automatic, high ability of anti-interference, exact, efficient and reliable during the applications.
Keywords
calibration; flowmeters; nozzles; automatic sonic nozzle; gas flow meter calibration; negative pressure method; Calibration; Educational institutions; Electronic mail; Fluid flow; Fluid flow measurement; Metrology; Pressure measurement; Auto Calibration; Gas flow meter; Negative pressure method; Sonic Nozzle;
fLanguage
English
Publisher
ieee
Conference_Titel
Electric Information and Control Engineering (ICEICE), 2011 International Conference on
Conference_Location
Wuhan
Print_ISBN
978-1-4244-8036-4
Type
conf
DOI
10.1109/ICEICE.2011.5778057
Filename
5778057
Link To Document