DocumentCode :
3291464
Title :
Experimental study of effects of coaxial cables in magnetic resonant wireless power transfer system
Author :
Shixing Yu ; Long Li
Author_Institution :
Xidian Univ., Xi´an, China
fYear :
2013
fDate :
14-18 April 2013
Firstpage :
1
Lastpage :
4
Abstract :
This paper analyzes the effects of coaxial cables in the magnetic resonant wireless power transfer (WPT) system. The experimental results show that the transfer efficiency of WPT system would change when different coaxial cables were connected to the source and load coils. Some special phenomena are revealed and a possible interpretation is proposed in this paper. Experiment results show that the proposed system can dramatically improve the efficiency and extend the power transfer distance. In the same size of MIT´s helix, the efficiency of the WPT system increased to near 50% at the distance of 4.8 meters, while near 50% of 2 meters by MIT in 2007. In addition, we succeed to light a low voltage bulb at the distance of 4.8 meters.
Keywords :
coaxial cables; inductive power transmission; magnetic resonance; coaxial cables; distance 4.8 m; load coils; magnetic resonant wireless power transfer system; source coils; Coaxial cables; Coils; Impedance; Magnetic resonance; Ports (Computers); Transmission line measurements; Wireless communication; Coaxial cable; Impedance matching; Parasitic capacitance; Wireless Power Transfer;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Wireless Symposium (IWS), 2013 IEEE International
Conference_Location :
Beijing
Type :
conf
DOI :
10.1109/IEEE-IWS.2013.6616724
Filename :
6616724