DocumentCode
3292053
Title
Derivation of coupling-of-modes parameters for SAW device analysis by means of boundary element method
Author
Hashimoto, Ken-Ya ; Yamaguchi, Masatsune
Author_Institution
Dept. of Electr. & Electron. Eng., Chiba Univ., Japan
fYear
1991
fDate
8-11 Dec 1991
Firstpage
21
Abstract
A method for derivation of coupling-of-modes (COM) parameters for surface acoustic wave (SAW) device analysis is proposed. Emphasis is laid upon the COM parameter derivation by means of the boundary element method (BEM) analysis, and the COM analysis of a floating electrode unidirectional transducer. Results have shown that the transducer characterization using the COM parameters derived from the BEM analysis agrees surprisingly with that obtained by the direct application of the BEM analysis. It is concluded that once the COM parameters are properly determined, the characterization of SAW interdigital transducers having a large number of fingers and an arbitrary geometry can be performed most precisely and rapidly
Keywords
acoustic transducers; boundary-value problems; surface acoustic wave devices; SAW device analysis; boundary element method; coupling-of-modes parameters; floating electrode unidirectional transducer; surface acoustic wave; Acoustic transducers; Acoustic waves; Boundary element methods; Electrodes; Fingers; Geometry; Polynomials; Surface acoustic wave devices; Surface acoustic waves; Surface fitting;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium, 1991. Proceedings., IEEE 1991
Conference_Location
Orlando, FL
Type
conf
DOI
10.1109/ULTSYM.1991.234123
Filename
234123
Link To Document