Title :
Low voltage pulsed magnetron with heating free excitation
Author_Institution :
Laminar Co., Moscow
Abstract :
This paper describes the results of research and development of low-voltage pulsed magnetrons with autoelectronic starting into operating conditions. Autoelectronic cathodes ensure an autoelectronic current greater than 1.2 mA. At constant voltage more than 1.5 kV was obtained. This ensures stable magnetron starting into operating conditions at the frequency of 2.4 GHz with pulse duration of τpuls-1 μs
Keywords :
UHF tubes; cathodes; magnetrons; starting; 1 mus; 1.2 mA; 1.5 kV; 2.4 GHz; LV pulsed magnetron; UHF tube; autoelectronic cathodes; autoelectronic starting; heating free excitation; low voltage operation; stable magnetron starting; Cathodes; Charge carrier processes; Electromagnetic heating; Frequency; Low voltage; Magnetic devices; Microelectronics; Microwave devices; Temperature;
Conference_Titel :
Vacuum Microelectronics Conference, 1996. IVMC'96., 9th International
Conference_Location :
St. Petersburg
Print_ISBN :
0-7803-3594-5
DOI :
10.1109/IVMC.1996.601862