• DocumentCode
    3293875
  • Title

    The influence of the radius of the contour on the orientation of the zero-temperature contoured SC-cut quartz resonator

  • Author

    Stevens, D.S. ; Tiersten, H.F.

  • Author_Institution
    AT&T Bell Labs., North Andover, MA, USA
  • fYear
    1991
  • fDate
    8-11 Dec 1991
  • Firstpage
    505
  • Abstract
    On account of small inaccuracies in the measured temperature derivatives of the elastic constants of quartz, only the nominal φ and θ angles of zero-temperature cut quartz resonators can be calculated. In previous work, the correction to the nominal φ angle was obtained from measurements on the third overtone of a contoured SC-cut quartz resonator at 25°C. The correction reported for the φ angle was 48.3´. The errors are corrected, and the revised calculation shows that not only do the magnitudes of the angles change, but also the signs. This is in conformity with measurement. Similarly, both the magnitude and sign of the temperature derivative of the effective piezoelectric constant for the C-mode differ from the earlier incorrect value. The calculations also show that the change in orientation with the radius of the contour for the third and fifth harmonic is significant in the SC cut as well as the fundamental
  • Keywords
    crystal resonators; φ angle; C-mode; effective piezoelectric constant; elastic constants; orientation; overtone; temperature derivatives; zero-temperature contoured SC-cut quartz resonator; Boundary conditions; Dielectrics; Electric potential; Equations; Error correction; Frequency; Piezoelectricity; Temperature; Thermoelasticity;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 1991. Proceedings., IEEE 1991
  • Conference_Location
    Orlando, FL
  • Type

    conf

  • DOI
    10.1109/ULTSYM.1991.234216
  • Filename
    234216