DocumentCode
3293875
Title
The influence of the radius of the contour on the orientation of the zero-temperature contoured SC-cut quartz resonator
Author
Stevens, D.S. ; Tiersten, H.F.
Author_Institution
AT&T Bell Labs., North Andover, MA, USA
fYear
1991
fDate
8-11 Dec 1991
Firstpage
505
Abstract
On account of small inaccuracies in the measured temperature derivatives of the elastic constants of quartz, only the nominal φ and θ angles of zero-temperature cut quartz resonators can be calculated. In previous work, the correction to the nominal φ angle was obtained from measurements on the third overtone of a contoured SC-cut quartz resonator at 25°C. The correction reported for the φ angle was 48.3´. The errors are corrected, and the revised calculation shows that not only do the magnitudes of the angles change, but also the signs. This is in conformity with measurement. Similarly, both the magnitude and sign of the temperature derivative of the effective piezoelectric constant for the C-mode differ from the earlier incorrect value. The calculations also show that the change in orientation with the radius of the contour for the third and fifth harmonic is significant in the SC cut as well as the fundamental
Keywords
crystal resonators; φ angle; C-mode; effective piezoelectric constant; elastic constants; orientation; overtone; temperature derivatives; zero-temperature contoured SC-cut quartz resonator; Boundary conditions; Dielectrics; Electric potential; Equations; Error correction; Frequency; Piezoelectricity; Temperature; Thermoelasticity;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium, 1991. Proceedings., IEEE 1991
Conference_Location
Orlando, FL
Type
conf
DOI
10.1109/ULTSYM.1991.234216
Filename
234216
Link To Document