• DocumentCode
    3293893
  • Title

    The impact on testing precision of solar modules by the correction parameter of solar simulator

  • Author

    Yongqing, Wang ; Ailing, Cai ; Rongxia, Sun

  • Author_Institution
    Coll. of Electron. & Informational Eng., Hebei Univ., Baoding, China
  • fYear
    2009
  • fDate
    6-10 July 2009
  • Firstpage
    476
  • Lastpage
    478
  • Abstract
    When the testing temperature has a deviation to 25degC and an unsuitable setting of the correction parameter, the result of the solar simulator shows an error value which has a large distance with the correct one. The paper tries to prove that the precision of solar simulator has great relationship not only with the temperature coefficients but also the curve correction factor. Finally, the correct setting value is obtained through research and the error of the research result is less than 1% of the value with in the temperature of 15-37degC.
  • Keywords
    solar cells; correction parameter; solar modules; solar simulator; temperature 15 C to 37 C; testing precision; Circuit testing; Current measurement; Electrical resistance measurement; Electronic equipment testing; Error correction; IEC standards; Measurement standards; Temperature distribution; Virtual manufacturing; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Physical and Failure Analysis of Integrated Circuits, 2009. IPFA 2009. 16th IEEE International Symposium on the
  • Conference_Location
    Suzhou, Jiangsu
  • ISSN
    1946-1542
  • Print_ISBN
    978-1-4244-3911-9
  • Electronic_ISBN
    1946-1542
  • Type

    conf

  • DOI
    10.1109/IPFA.2009.5232603
  • Filename
    5232603