DocumentCode
3295444
Title
On-the-field calibration of an array of sensors
Author
Dorveaux, E. ; Vissiere, D. ; Petit, N.
Author_Institution
Centre Autom. et Syst., MINES ParisTech, Paris, France
fYear
2010
fDate
June 30 2010-July 2 2010
Firstpage
6795
Lastpage
6802
Abstract
We address the problem of the calibration of an array of sensors by investigating theoretically and experimentally the case of 2 three-axis sensors. Our focus is on magnetometers that can be used in a low-cost inertial navigation system. Usual errors (misalignments, non-orthogonality, scale factors, biases) are accounted for. The proposed calibration method requires no specific calibration hardware. Instead, we solely use the fact that, if the sensor is properly calibrated, the norm of the sensed field must remain constant irrespective of the sensors orientation. Several strategies of calibration for an array of sensors are described along with the impact of (unavoidable) field disturbances. Experiments conducted with a couple of magneto-resistive magnetometers and data fusion results illustrate the relevance of the approach.
Keywords
calibration; inertial navigation; magnetometers; sensor arrays; field calibration; low cost inertial navigation system; magneto resistive magnetometers; misalignments; non-orthogonality; scale factor; sensor array; three axis sensor; Calibration; Couplings; Embedded computing; Hardware; Inertial navigation; Magnetic sensors; Magnetometers; Motion estimation; Sensor arrays; Sensor phenomena and characterization;
fLanguage
English
Publisher
ieee
Conference_Titel
American Control Conference (ACC), 2010
Conference_Location
Baltimore, MD
ISSN
0743-1619
Print_ISBN
978-1-4244-7426-4
Type
conf
DOI
10.1109/ACC.2010.5531632
Filename
5531632
Link To Document