• DocumentCode
    3296199
  • Title

    Facing more than moore, is magnetic microscopy the new Swiss knife for 3D defect localization in SiP?

  • Author

    Perdu, P. ; Infante, Fulvio

  • Author_Institution
    DCT, CNES, Toulouse, France
  • fYear
    2010
  • fDate
    5-9 July 2010
  • Firstpage
    1
  • Lastpage
    8
  • Abstract
    So far, most of the defects at system level are assembly related. This trend obviously concerns Systems in Package, Stacked dies, Packages on Package devices, passive integration, integration of logic, power, wireless, analog, sensor and actuator in the same packaged device... All these Systems in Package defy our failure localization tools. For the first time, we have to face non transparent material, massive 3D structure with mandatory long working distance and need of relatively high spatial resolution. Magnetic microscopy has the ability do this as long as we are able to adapt its principle to the mandatory 3D sensitivity and resolution. We have developed a global 3D approach based on simulation in order to target μm resolution at long working distance.
  • Keywords
    system-in-package; 3D defect localization; logic integration; magnetic microscopy; mandatory 3D sensitivity; packages on package devices; passive integration; spatial resolution; stacked dies; systems in package; Actuators; Assembly systems; Logic devices; Magnetic materials; Magnetic sensors; Micromagnetics; Packaging; Sensor systems; Spatial resolution; Wireless sensor networks;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Physical and Failure Analysis of Integrated Circuits (IPFA), 2010 17th IEEE International Symposium on the
  • Conference_Location
    Singapore
  • ISSN
    1946-1542
  • Print_ISBN
    978-1-4244-5596-6
  • Type

    conf

  • DOI
    10.1109/IPFA.2010.5532003
  • Filename
    5532003