DocumentCode :
3296978
Title :
A new approach of dynamic pinhole SPECT imaging for evaluation of sympathetic nervous system function in animal models of cardiac hypertrophy
Author :
Hu, Jicun ; Sitek, Arkadiusz ; Reutter, Bryan W. ; Huesman, Ronald H. ; Gullberg, Grant T.
Author_Institution :
Dept. of Nucl. Medicine & Functional Imaging, Lawrence Berkeley Nat. Lab., CA
Volume :
5
fYear :
2005
fDate :
23-29 Oct. 2005
Firstpage :
2542
Lastpage :
2546
Abstract :
Typically 123I-MIBG is used for the study of innervation and function of the sympathetic nervous system in heart failure. The protocol involves two studies: first a planar or SPECT scan is performed to measure initial uptake of the tracer, followed some 3-4 hours later by another study measuring the wash-out of the tracer from the heart. A fast wash-out is indicative of a compromised heart. In this work, a dual head pinhole SPECT system was used for imaging the distribution and kinetics of 123I-MIBG in the myocardium of spontaneous hypertensive rats (SHR) and normotensive Wistar Kyoto (WKY) rats. The system geometry was calibrated based on a nonlinear point projection fitting method using a three-point source phantom. The angle variation effect of the parameters was modeled with a sinusoidal function. A dynamic acquisition was performed by injecting 123I-MIBG into rats immediately after starting the data acquisition. The detectors rotated continuously traversing 360deg every 90 seconds. We applied the FADS method to obtain time activity curves in the blood pool and myocardium. Since the initial injection bolus is too fast to obtain a consistent tomographic data set in the first minute of the study, we applied the FADS method directly to projections during the first rotation. In the future, the method will be applied to determine if there are differences in the kinetics between SHR and WKY rats. This approach requires less time by replacing the delayed scan at 3-4 hours after injection with a dynamic acquisition of 90 to 120 minutes
Keywords :
blood; calibration; cardiology; medical image processing; neurophysiology; phantoms; single photon emission computed tomography; 123I-MIBG distribution; 123I-MIBG kinetics; FADS method; angle variation effect; animal models; blood; calibration; cardiac hypertrophy; dynamic pinhole SPECT imaging; heart failure; initial tracer uptake; myocardium; nonlinear point projection fitting; normotensive Wistar Kyoto rats; spontaneous hypertensive rats; sympathetic nervous system function; three-point source phantom; time activity curves; tracer wash-out; Animals; Heart; Hypertension; Kinetic theory; Magnetic heads; Myocardium; Performance evaluation; Protocols; Rats; Sympathetic nervous system;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2005 IEEE
Conference_Location :
Fajardo
ISSN :
1095-7863
Print_ISBN :
0-7803-9221-3
Type :
conf
DOI :
10.1109/NSSMIC.2005.1596857
Filename :
1596857
Link To Document :
بازگشت