• DocumentCode
    3299010
  • Title

    Fluorescence resonance energy transfer detection of mouse immunoglobulin G and Octamer-4 on protein nanoarray

  • Author

    Tran, Phat L. ; Tchao, Yee ; Yoon, Jeong-Yeol

  • Author_Institution
    Biomed. Eng. Grad. Interdiscipl. Program, Univ. of Arizona, Tucson, AZ
  • fYear
    2009
  • fDate
    9-11 April 2009
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    An alternative approach for fabricating a protein array at nanoscale (<100 nm) is suggested with a capability of characterization and/or localization of multiple components on a nanoarray. Basically, fluorescent micro- and nanospheres each conjugated with different proteins are size-dependently self-assembled (SDSA) onto these nanometer wells that were created on the polymethyl methacrylate (PMMA) substrate by electron beam lithography (EBL). Particles of different diameters are added serially, and electrostatically attached to the corresponding wells through electrostatic attraction between the carboxylic groups of the spheres and p-doped silicon substrate underneath the PMMA layer. Target detection utilizes fluorescence resonance energy transfer (FRET) from fluorescent beads to target (mouse immunoglobulin G = mIgG or Octamer-4 = Oct4) and its antibody bound on the beads. The 180 nm blue beads are conjugated with mIgG to capture anti-mIgG-FITC. The 50 nm green and 100 nm yellow-green beads are conjugated with anti-Oct4 to capture Oct4 peptides; where the secondary anti-Oct4 tagged with phycoerythrin via F(ab)2 fragment is then added to function as an indicator of Oct4 detection. These protein-conjugated particles are added serially from the largest to the smallest and the particles are successfully self-assembled to the respective nanometer wells to achieve size-dependent self-assembly. FRET signals are detected through fluorescence and confocal microscopes, and further confirmed by Fluorolog3 spectrofluorometer. Therefore, SDSA is a valuable approach for the fabrication of multiple components array; and FRET is a useful biorecognition technique for the detection of mIgG, Oct4 or other targets of interest.
  • Keywords
    biosensors; fluorescence; proteins; Fluorolog3 spectrofluorometer; Octamer-4; electron beam lithography; fluorescence resonance energy transfer detection; microspheres; mouse immunoglobulin G; nanospheres; polymethyl methacrylate; protein nanoarray; Electron beams; Electrostatics; Energy exchange; Fluorescence; Immune system; Lithography; Mice; Proteins; Resonance; Self-assembly;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Complex Medical Engineering, 2009. CME. ICME International Conference on
  • Conference_Location
    Tempe, AZ
  • Print_ISBN
    978-1-4244-3315-5
  • Electronic_ISBN
    978-1-4244-3316-2
  • Type

    conf

  • DOI
    10.1109/ICCME.2009.4906682
  • Filename
    4906682