DocumentCode :
3304145
Title :
The use of an unified diagnostic approach to predict the operating deterioration of three-phase induction motors
Author :
Carvalheiro, J.M.N. ; Ribeiro, P.M.P. ; Goncalves, Monira ; Cardoso, A.J.M.
Author_Institution :
Pegop-Energia Electrica S.A., Portugal
fYear :
35886
fDate :
30 Mar-1 Apr1998
Firstpage :
157
Lastpage :
160
Abstract :
The paper highlights the advantages of using not only one, but different diagnostic systems, in order to effectively predict the operating deterioration of three-phase induction motors in a way that is both much more reliable and convincing than the one resulting from each different strategy when used alone. Special focus is given to the use of Park´s vector approach. The criteria actually in use at Pego power station (Portugal), for the maintenance management of critical induction motors, is based on this unified diagnostics strategy
Keywords :
induction motors; Park´s vector approach; Portugal; maintenance management; operating deterioration; power station; three-phase induction motors; unified diagnostic approach;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Power Station Maintenance - Profitability Through Reliability, 1998. First IEE/IMechE International Conference on (Conf. Publ. No. 452)
Conference_Location :
Edinburgh
ISSN :
0537-9989
Print_ISBN :
0-85296-699-7
Type :
conf
DOI :
10.1049/cp:19980080
Filename :
674062
Link To Document :
بازگشت