• DocumentCode
    3307288
  • Title

    Junction temperature estimation for an advanced active power cycling test

  • Author

    Choi, U.M. ; Blaabjerg, F. ; Jorgensen, S.

  • Author_Institution
    Dept. of Energy Technol., Aalborg Univ., Aalborg, Denmark
  • fYear
    2015
  • fDate
    1-5 June 2015
  • Firstpage
    2944
  • Lastpage
    2950
  • Abstract
    On-state collector-emitter voltage (VCE) is a good indicator to determine the wear-out condition of power device modules. Further, it is a one of the Temperature Sensitive Electrical Parameters (TSEPs) and thus can be used for junction temperature estimation. In this paper, the junction temperature estimation method using on-state VCE for an advanced active power cycling test is proposed. The concept of the advanced power cycling test is explained first. Afterwards the junction temperature estimation method using on-state VCE and current is presented. Further, the method to improve the accuracy of the maximum junction temperature estimation is also proposed. Finally, the validity and effectiveness of the proposed method is confirmed by experimental results.
  • Keywords
    estimation theory; power electronics; temperature measurement; TSEP; advanced active power cycling test; junction temperature estimation method; maximum junction temperature estimation; on-state VCE; on-state collector-emitter voltage; power device modules; temperature sensitive electrical parameters; wear-out condition; Current measurement; Estimation; Junctions; Temperature; Temperature measurement; Temperature sensors; Voltage measurement; Power cycling test; TSEP; junction temperature estimation; power device module;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and ECCE Asia (ICPE-ECCE Asia), 2015 9th International Conference on
  • Conference_Location
    Seoul
  • Type

    conf

  • DOI
    10.1109/ICPE.2015.7168194
  • Filename
    7168194