DocumentCode :
330939
Title :
A dynamic mechanical load emulation test facility to evaluate the performance of AC inverters
Author :
Hewson, C.R. ; Asher, G.M. ; Sumner, M.
Author_Institution :
Nottingham Univ., UK
fYear :
1998
fDate :
21-23 Sep 1998
Firstpage :
206
Lastpage :
211
Abstract :
This paper outlines the design, construction and operation of the test facility. Its philosophy is primarily described with reference to the hardware based load emulator rig. A discussion of the global control structure designed to operate both the hardware and software tools is provided. The target mechanical load is a passenger lift and the paper outlines the mechanical characteristics of this application. Finally practical results for the hardware test facility show it is now fully operational
Keywords :
invertors; AC inverters performance; dynamic mechanical load emulation test facility; global control structure; hardware based load emulator rig; hardware tools; induction motor drives; mechanical characteristics; software tools;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Power Electronics and Variable Speed Drives, 1998. Seventh International Conference on (Conf. Publ. No. 456)
Conference_Location :
London
ISSN :
0537-9989
Print_ISBN :
0-85296-704-7
Type :
conf
DOI :
10.1049/cp:19980525
Filename :
732040