• DocumentCode
    330957
  • Title

    DSP controlled auxiliary resonant commutated pole inverter without switch status sensors

  • Author

    Pickert, V. ; Johnson, C.M.

  • Author_Institution
    Newcastle upon Tyne Univ., UK
  • fYear
    1998
  • fDate
    21-23 Sep 1998
  • Firstpage
    650
  • Lastpage
    655
  • Abstract
    Cycle by cycle calculations are performed in a DSP to determine the optimum switching instants for both auxiliary and main devices in an auxiliary resonant commutated pole inverter without the need for additional current sensors. Results are presented demonstrating significant reductions in overall loss, when compared to a hard-switched inverter, without degradation in PWM controllability
  • Keywords
    resonant power convertors; DSP; PWM controllability; auxiliary resonant commutated pole inverter; cycle by cycle calculations; loss reductions; optimum switching instants;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Power Electronics and Variable Speed Drives, 1998. Seventh International Conference on (Conf. Publ. No. 456)
  • Conference_Location
    London
  • ISSN
    0537-9989
  • Print_ISBN
    0-85296-704-7
  • Type

    conf

  • DOI
    10.1049/cp:19980602
  • Filename
    732136