• DocumentCode
    3310585
  • Title

    Radiometric 5 mm Wavelength Receiver

  • Author

    Kuzmin, S.E. ; Muskin, Y.N. ; Radzikhovsky, V.N.

  • Author_Institution
    OJS Sci.-Production Enterprise SATURN, Kiev
  • Volume
    2
  • fYear
    2007
  • fDate
    25-30 June 2007
  • Firstpage
    769
  • Lastpage
    771
  • Abstract
    The development of high-sensitive direct detection radiometric modules with low-noise input amplifiers in 5 mm wave band is discussed. Two versions of modules have been developed. The module designed for atmospheric investigation operated in frequency band 56.6 plusmn 0.25 GHz and had temperature sensitivity 35 mK/Hz1/2. The module for biological investigation operated in frequency band 60...65 GHz and had temperature sensitivity 12 mK/Hz1/2.
  • Keywords
    amplifiers; millimetre wave receivers; radiometers; direct radiometric modules detection; low-noise input amplifiers; mm wave band; radiometric receiver; temperature sensitivity; wavelength 5 mm; Atmospheric waves; Band pass filters; Circuit noise; Detectors; Frequency; Low-noise amplifiers; MMICs; Microwave radiometry; Radiofrequency amplifiers; Temperature sensors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Physics and Engineering of Microwaves, Millimeter and Submillimeter Waves and Workshop on Terahertz Technologies, 2007. MSMW '07. The Sixth International Kharkov Symposium on
  • Conference_Location
    Kharkov
  • Print_ISBN
    1-4244-1237-4
  • Type

    conf

  • DOI
    10.1109/MSMW.2007.4294808
  • Filename
    4294808