DocumentCode
3314684
Title
An experimental study to investigate the effects of partial discharges (PD), of electric field and of relative humidity during surface PD tests on thin polymer films
Author
Centurioni, L. ; Coletti, G. ; Guastavino, F.
Author_Institution
Dipartimento di Ingegneria Elettrica, Genova Univ., Italy
fYear
1999
fDate
1999
Firstpage
239
Abstract
It is possible to conceive that the degradation of thin polymer films subjected to surface partial discharges (PD) is due both to the direct PD action and to an electrical aging process due to the electric field acting in the film below the target micro-areas of PD during the instants of discharges. Therefore an innovative testing procedure has been implemented to check such an assertion. Three different polyimide 25 μm thick films have been selected for the surface PD tests. Such tests have been carried out at different humidities till breakdown of the films. The results (lifetimes) obtained in the present case showed no evidence of a contribution of the above electrical aging factor to the films degradation. However this outcome cannot be generalised, as the electrical aging phenomena depends both on the thickness and on the dielectric strength of the films under consideration. When necessary, the testing procedure presented here can be applied to check the situation
Keywords
electric strength; humidity; organic insulating materials; partial discharges; polymer films; 25 mum; dielectric strength; electrical aging; film thickness; polyimide; relative humidity; surface partial discharge tests; thin polymer films; Aging; Electric breakdown; Humidity; Partial discharges; Polyimides; Polymer films; Surface discharges; Testing; Thermal degradation; Thick films;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation and Dielectric Phenomena, 1999 Annual Report Conference on
Conference_Location
Austin, TX
Print_ISBN
0-7803-5414-1
Type
conf
DOI
10.1109/CEIDP.1999.804635
Filename
804635
Link To Document