• DocumentCode
    3314764
  • Title

    Change in partial discharge properties of a void in LDPE

  • Author

    Mizutani, T. ; Kondo, T. ; Nakao, K.

  • Author_Institution
    Dept. of Electr. Eng., Nagoya Univ., Japan
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    257
  • Abstract
    Partial Discharges (PD) cause the degradation of insulating materials and govern the lifetime of high-voltage power apparatus and cables. Therefore, it is important to understand the PD behaviors in the aging process. In this paper, partial discharges and their current shapes of low-density polyethylene (LDPE) with a void were measured. The PD φ-q-n pattern and the current shape changed remarkably with time and were related to each other. They depended not only upon the size and shape of voids but also on the degree of PD degradation. This suggests the possibility of insulation diagnosis using PD characteristics
  • Keywords
    ageing; insulation testing; partial discharges; polyethylene insulation; voids (solid); LDPE; PD; PD φ-q-n pattern; PD degradation; aging process; current shapes; high-voltage power apparatus; insulating material degradation; insulation diagnosis; partial discharge properties; void shape; void size; Aging; Current measurement; Degradation; Electric breakdown; Electrodes; Insulation; Partial discharges; Resistors; Shape measurement; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena, 1999 Annual Report Conference on
  • Conference_Location
    Austin, TX
  • Print_ISBN
    0-7803-5414-1
  • Type

    conf

  • DOI
    10.1109/CEIDP.1999.804639
  • Filename
    804639