DocumentCode :
3317873
Title :
Experimental results of power combining and phase-locking magnetrons for accelerator applications
Author :
Treado, T.A. ; Zurk, L.M. ; Smith, R.S., III ; Hansen, T.A. ; Barry, J.D. ; Jenkins, D.J. ; Thomas, G.E.
Author_Institution :
Varian Associates, Inc., Beverely, MA, USA
fYear :
1990
fDate :
9-12 Dec. 1990
Firstpage :
541
Lastpage :
544
Abstract :
It is demonstrated that injection-locked magnetrons can be used to drive a moderate Q cavity without a circulator with excellent interpulse phase coherency. A 3-dB hybrid coupler provides the avenue for both injection locking and power combining of magnetron pairs. Better intrapulse phase coherency than has been demonstrated is anticipated when lower Q magnetrons or lower gains are used. The cavity transient impedance does not preclude the magnetrons from filling the cavity, at least when the cavity fill time is less than the magnetron phase lock time.<>
Keywords :
magnetrons; particle accelerator accessories; waveguide couplers; Q cavity; accelerator applications; cavity fill time; cavity transient impedance; hybrid coupler; interpulse phase coherency; intrapulse phase coherency; phase-locking magnetrons; power combining; Couplings; Filling; Impedance; Injection-locked oscillators; Magnetrons;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electron Devices Meeting, 1990. IEDM '90. Technical Digest., International
Conference_Location :
San Francisco, CA, USA
ISSN :
0163-1918
Type :
conf
DOI :
10.1109/IEDM.1990.237139
Filename :
237139
Link To Document :
بازگشت