• DocumentCode
    331821
  • Title

    Measurement of EMI in PLC circuits

  • Author

    Botha, Matthys

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Stellenbosch Univ.
  • fYear
    1998
  • fDate
    7-8 Sep 1998
  • Firstpage
    323
  • Lastpage
    326
  • Abstract
    Many high-power switching devices generate high-frequency noise when operating. This noise falls well into the power line carrier (PLC) frequency range. Thus it may have a degrading influence on the PLC signal integrity and reliability. Some measurements were undertaken to determine the extent of electromagnetic noise pollution in the PLC circuits; this paper contains a summary of some of the more important aspects to keep in mind when doing such measurements
  • Keywords
    electric noise measurement; electromagnetic interference; frequency measurement; power cables; power system control; EMI; electromagnetic noise pollution; high-frequency noise; high-power switching devices; measurements; power line carrier; Circuit noise; Electromagnetic interference; Frequency; Impedance; Instruments; Noise measurement; Pollution measurement; Programmable control; Signal analysis; Voltmeters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Communications and Signal Processing, 1998. COMSIG '98. Proceedings of the 1998 South African Symposium on
  • Conference_Location
    Rondebosch
  • Print_ISBN
    0-7803-5054-5
  • Type

    conf

  • DOI
    10.1109/COMSIG.1998.736974
  • Filename
    736974