Abstract :
Nowadays the doubly fed induction machine is often used as generator in high power windenergy systems. Because of the use of two converters in the generator´s rotor circuit bearing damages can occurred specially for this type of machine. So the aim is to reduce the common mode voltage as one cause of bearing currents. Instead of a classic space vector modulation this paper presents the simulation of an enhanced direct power control.
Keywords :
asynchronous generators; machine control; power control; rotors; bearing current; common mode voltage; common mode voltage reduction; direct power control; doubly fed induction generators; rotor circuit bearing damage; windenergy systems; Circuits; Equations; Induction generators; Power control; Power generation; Rotors; Stators; Torque control; Voltage control; Wind turbines; Common mode voltage; Direct Power Control; Doubly fed induction generator;