• DocumentCode
    3321256
  • Title

    Design for EMI compliance for a compact 3000 W system

  • Author

    Chouinard, Jean-Francois ; Duguay, Louis

  • Author_Institution
    Northern Telecom Ltd., Montreal, Que., Canada
  • fYear
    1997
  • fDate
    19-23 Oct 1997
  • Firstpage
    637
  • Lastpage
    642
  • Abstract
    Low levels of electromagnetic interference emissions of power equipment are mandatory to avoid interactions between the power system and other telecommunication equipment located in close proximity. No malfunctions due to EMI are tolerable between different types of equipment. The power system should be designed such that it is immune to the emission of other equipment, Also the power system EMI noise must be below the acceptable limit of other type of telecommunication equipment. The stringent Class B requirements of emission of FCC and CISPR are replacing Class A as the standard to be achieved for a telecommunication power system. The paper describes all the design philosophy for EMI compliance of a typical compact power system. An example of a 3000 W power system that meets CISPR22 Class B and FCC Class B is demonstrated
  • Keywords
    electromagnetic interference; telecommunication power supplies; 3 kW; CISPR; CISPR22 Class B; Class B requirements; EMI compliance; FCC; FCC Class B; compact power system; conductive emissions; electromagnetic interference emissions; power equipment; power system EMI noise; radiated emissions; telecommunication equipment; telecommunication power system; Attenuation; Circuits; Electromagnetic interference; FCC; Power cables; Power system management; Power system measurements; Power systems; Rectifiers; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Telecommunications Energy Conference, 1997. INTELEC 97., 19th International
  • Conference_Location
    Melbourne, Vic.
  • Print_ISBN
    0-7803-3996-7
  • Type

    conf

  • DOI
    10.1109/INTLEC.1997.646062
  • Filename
    646062