DocumentCode
3321935
Title
Dynamic performance analysis and identification of optics-camera testing-table
Author
Qi Enbing ; Fang Zhenyong
Author_Institution
Center for Precision Eng., Harbin Inst. of Technol., Harbin, China
Volume
2
fYear
2013
fDate
16-19 Aug. 2013
Firstpage
864
Lastpage
867
Abstract
Testing-equipment for calibrating spaced-optical cameras is in desperate need nowadays due to a growing of spaced-camera production. The accuracy gets more precise which put a great challenge on design and manufacturing of testing-equipment. In order to overcome the problem, a novel 4-axis testing-equipment has been designed, manufactured and tested. A dynamic model is established and calculated by FEA method. An experiment to identify dynamic parameters is done. The experimental results find great agreement with the dynamic simulation results data, which verifies the validity of the dynamic model we established.
Keywords
calibration; cameras; test equipment; 4-axis testing-equipment; FEA method; dynamic model; dynamic performance analysis; optics-camera testing-table; Accuracy; Adaptive optics; Cameras; Integrated optics; Mathematical model; Shape; Testing; Camera calibrating; Dynamic analysis; Dynamic identification; Testing table design;
fLanguage
English
Publisher
ieee
Conference_Titel
Electronic Measurement & Instruments (ICEMI), 2013 IEEE 11th International Conference on
Conference_Location
Harbin
Print_ISBN
978-1-4799-0757-1
Type
conf
DOI
10.1109/ICEMI.2013.6743156
Filename
6743156
Link To Document