Title :
Ultrasonic reflection tomography and tomographic parameter extraction for post-discotomic scarring diagnostics
Author :
Pesavento, A. ; Ermert, H. ; Zeitvogel, E. Broll ; Grifka, J.
Author_Institution :
Dept. of Electr. Eng., Ruhr-Univ., Bochum, Germany
Abstract :
An ultrasonic imaging system is presented for diagnostics of post discotomic scarring. The system consists of a conventional B-mode imaging system, using a 5 MHz sector scanner. The scanner is laterally moved over the patients back along a linear line. Thus several images of the same cross sectional plane are acquired by sampling the RF echo data. This data has been used for both, spatial compounding of the B-mode images and multidirectional extraction of the spectral parameters attenuation and backscattering
Keywords :
acoustic tomography; backscatter; biomedical ultrasonics; medical image processing; parameter estimation; surgery; ultrasonic absorption; ultrasonic reflection; ultrasonic scattering; 5 MHz; 5 MHz sector scanner; RF echo data sampling; attenuation; back surgery; conventional B-mode imaging system; cross sectional plane; laterally movements; linear line; medical diagnostic computing; multidirectional extraction; post-discotomic scarring diagnostics; postoperative relapsing complaints; spatial compounding; spectral parameters extraction; tomographic parameter extraction; ultrasonic reflection tomography; Attenuation; Back; Backscatter; Frequency dependence; Parameter extraction; Reflection; Speckle; Tomography; Transducers; Ultrasonic imaging;
Conference_Titel :
Ultrasonics Symposium, 1997. Proceedings., 1997 IEEE
Conference_Location :
Toronto, Ont.
Print_ISBN :
0-7803-4153-8
DOI :
10.1109/ULTSYM.1997.661856