DocumentCode :
3322469
Title :
Screening of pretreatment parameters for novel solid-state ISE-based soil extractable potassium detection
Author :
Zhang Linan ; Zhang Miao
Author_Institution :
Key Lab. on Modern Precision Agric. Syst. Integration Res. of Minist. of Educ., China Agric. Univ., Beijing, China
Volume :
2
fYear :
2013
fDate :
16-19 Aug. 2013
Firstpage :
947
Lastpage :
953
Abstract :
Soil potassium testing plays an important role in soil fertilizer recommendation and site-specific fertilization. Conventional detection methods, including soil sampling, sample pretreatment and nutrient determination, are time-consuming and expensive. Ion-selective electrode (ISE) shows great potential in soil macronutrient detection because of its obvious advantages on rapid response, inexpensive cost, simple use and easy integration. In this paper, preliminary experiments were conducted to evaluate the feasibility of self-designed all-solid-state potassium ISE for soil extractable potassium detection with an automatic detection platform. The influences of soil pretreatment parameters, especially the extraction parameters, were discussed. Testing results indicated that NH4 cation existing in 1 mol/L NH4OAc extracting solution were too high to greatly degrade the potassium ISE performance. The optimized soil pretreatment parameters to obtain soil potassium extracts for ISE method was shaking 2.5g soil with 25mL Kelowna solution (soil-to-solution ratio 1:10) for 15 minutes. Under these optimized pretreatment parameters, the range of such potassium ISE could detect was from 4.8mg/L to 370.0mg/L. And there were good consistency and correlation between the results determined by potassium ISE and conventional method. It indicted that self-designed all-solid-state potassium ISE combined with the automatic detection platform could basically meet the need of soil extractable potassium rapid detection.
Keywords :
agriculture; fertilisers; geophysical techniques; potassium; soil; automatic detection platform; extraction parameters; ion-selective electrode; site-specific fertilization; soil fertilizer recommendation; soil macronutrient detection; soil pretreatment parameters; solid-state ISE-based soil extractable potassium detection; Conferences; Electrodes; Instruments; Soil; Soil measurements; Standards; Testing; ion-selective electrode; soil extractable potassium detection; soil extracting solution; soil pretreatment;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electronic Measurement & Instruments (ICEMI), 2013 IEEE 11th International Conference on
Conference_Location :
Harbin
Print_ISBN :
978-1-4799-0757-1
Type :
conf
DOI :
10.1109/ICEMI.2013.6743188
Filename :
6743188
Link To Document :
بازگشت