    We have been working to develop and implement faster synchrotron-based X-ray fluorescence computed tomography (XFCT) methods for the mapping of trace metals in biological samples. As practiced now, the XFCT image acquisition process is slow (on the order of 1 or more hours per slice), which severely limits the ability to perform 3D imaging and to image multiple samples for sake of comparison and improved experimental statistics. This is because the data needed for tomographic reconstruction are acquired line-by-line in a first-generation tomographic geometry. Recently, we have been demonstrated the feasibility of using emission tomography systems for synchrotron X-ray fluorescence computer tomography. The proposed detection system combines high-resolution semiconductor detectors with multiple-pinhole apertures. The most promising acquisition mode involves using a sheet-collimated beam to illuminate a single plane through the object, which can then be directly imaged through the pinholes without need for tomographic reconstruction. Monte Carlo and experimental studies demonstrated the potential for order-of-magnitude improvements in SNR or imaging speed using this strategy. Some have found this surprising since the use of a pinhole collimator greatly reduces the detection efficiency of the system. In the present paper, we derive analytic figures of merit based on the ideal observer signal to noise ratio for the two geometries. These FOMs provide simple analytic insight into the reason for the improvement obtained with the pinhole-based system: the low detection efficiency is more than compensated for by avoiding the ill-posedness of tomographic reconstruction. The derived FOMs also provide a basis for performing system optimization.
  • Keywords
    Monte Carlo methods; X-ray emission spectra; biomedical equipment; computerised tomography; semiconductor counters; synchrotron radiation; Monte Carlo methods; SNR comparison; X-ray fluorescence computed tomography; X-ray fluorescence imaging; acquisition strategies; computerised tomography; emission tomography systems; figure of merit; high resolution semiconductor detectors; multiple pinhole apertures; sheet collimated beam; synchrotron based XFCT; trace metal mapping; Computed tomography; Detectors; Fluorescence; Geometry; Image reconstruction; Optical imaging; Signal to noise ratio; Statistics; Synchrotrons; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
  • Conference_Location
    Orlando, FL
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-3961-4
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2009.5401580
  • Filename
    5401580