• DocumentCode
    3325629
  • Title

    Evaluation of an iterative cascade gamma ray correction algorithm for non-standard PET nuclides at various counting statistics in high resolution small animal PET imaging

  • Author

    Ju-Chieh Cheng ; Agbeko, N. ; O´Sullivan, J. ; Laforest, R.

  • Author_Institution
    Sch. of Med., Dept. of Radiol., Washington Univ., St. Louis, MO, USA
  • fYear
    2009
  • fDate
    Oct. 24 2009-Nov. 1 2009
  • Firstpage
    2842
  • Lastpage
    2845
  • Abstract
    We describe an evaluation of an iterative cascade gamma ray correction algorithm which was developed to improve the quantitative accuracy of small animal PET imaging with non-standard PET nuclides. The cascade correction algorithm uses the emission image and the attenuation map of the object to compute the shape or the spatial distribution of the coincidences caused by the cascade gamma rays, and the distribution is then scaled to the measured coincidences similarly to the typical scatter estimation methods. The sinogram profiles of the cascade estimate were compared with those of the scatter estimate and the prompts - randoms, and the cascade fraction was evaluated at various counting statistics for various random fractions and count rates. A quick convergence for the shape and the magnitude of the cascade estimate was observed and found to be not sensitive to the number of counts or count rate within the frame. A higher variation of the cascade fraction was observed for frames with lower number of counts. In addition, a higher overestimation of the cascade fraction was observed for frames with a higher random fraction and/or with a lower number of counts. As a result, a calibration for the scaling of the cascade estimate was applied for the high random fraction and low count situations, and the improvement was demonstrated using the sinogram profiles.
  • Keywords
    gamma-ray scattering; iterative methods; medical image processing; positron emission tomography; attenuation map; counting statistics; gamma-ray coincidences; iterative cascade gamma ray correction algorithm; nonstandard PET nuclides; small animal PET imaging; Animals; Attenuation; High-resolution imaging; Image resolution; Iterative algorithms; Optical imaging; Positron emission tomography; Scattering; Shape measurement; Statistics;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
  • Conference_Location
    Orlando, FL
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-3961-4
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2009.5401641
  • Filename