• DocumentCode
    332637
  • Title

    Study of the voltage behavior of water tree deteriorated XLPE cables by signal current detection mode for insulation diagnosis

  • Author

    Kakuta, M.

  • Author_Institution
    Dept. for Power Cable R&D, Mitsubishi Cable Ind. Ltd., Tokyo, Japan
  • fYear
    1998
  • fDate
    27-30 Sep 1998
  • Firstpage
    487
  • Lastpage
    490
  • Abstract
    We report on the performances of the detected signal current during in-service insulation diagnosis of water tree deteriorated XLPE cables as a function of the behavior on applying a test voltage. The test voltage used was a commercial frequency- AC voltage. One of the specimens used had sufficient water in the water tree deterioration, another had no water in the deterioration
  • Keywords
    XLPE insulation; cable insulation; insulation testing; trees (electrical); AC test voltage; XLPE cables; insulation diagnosis; signal current detection mode; water tree; Admittance; Cable insulation; Character generation; Equations; Frequency; Leak detection; Signal detection; Signal generators; Trees - insulation; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulating Materials, 1998. Proceedings of 1998 International Symposium on
  • Conference_Location
    Toyohashi
  • Print_ISBN
    4-88686-050-8
  • Type

    conf

  • DOI
    10.1109/ISEIM.1998.741788
  • Filename
    741788