Abstract
This paper presents the results of the measurements of the field homogeneity according to the electromagnetic compatibility (EMC) standard IEC 1000-4-3 in a semianechoic shielded room with different kinds of absorbers on the floor. Comparison is made between four configurations on the floor: ground plane, pyramid foam filled with carbon (0.6 m long), ferrite panels, ferrite panels and pyramid foam filled with carbon
Keywords
anechoic chambers; electromagnetic compatibility; electromagnetic shielding; electromagnetic wave absorption; ferrites; measurement standards; 0.6 m; EMC standard; IEC 1000-4-3; absorbers; carbon filled pyramid foam; electromagnetic compatibility standard; ferrite panels; floor; ground plane; measurement results; semianechoic chamber homogeneity; semianechoic shielded room; Anechoic chambers; Electric variables measurement; Electromagnetic compatibility; Electromagnetic devices; Electromagnetic measurements; Europe; Ferrites; Floors; IEC standards; Immunity testing;