DocumentCode
3328773
Title
Analysys and verification of calibration methods for fully polarimetric W-band radiometer
Author
Kim, Sung-Hyun ; Moon, Nam-Won ; Kim, Yong-Hoon
Author_Institution
Sch. of Inf. & Mechatron., Gwangju Inst. of Sci. & Technol., Gwangju, South Korea
fYear
2010
fDate
25-30 July 2010
Firstpage
562
Lastpage
565
Abstract
The design method of calibration standard of fully polarimetric radiometer to measure the Stokes parameters at W-band is proposed. The information of 45° in a linear and a circular polarization are calibrated using the wire grid with thin Teflon substrate and the retardation plate which was implemented by dielectric plate with grove. The calibration standards show good performance on orthogonal channel polarization mixing (-17 to -25 dB), on mixing from the orthogonal channel into the polarimetric channels (-10.1 to -6.0 dB), and on mixing between polarization channels (-3.2 to -5.8 dB).
Keywords
calibration; polarisation; radiometers; Stokes parameters; Teflon substrate; W-band; circular polarization; dielectric plate; linear polarization; orthogonal channel polarization mixing; plate grid; polarimetric channels; polarimetric radiometer; retardation plate; Calibration; Loss measurement; Microwave radiometry; Stokes parameters; Substrates; Temperature measurement; Wire; W-band; calibration; plate grid; polarization; radiometer; retardation plate;
fLanguage
English
Publisher
ieee
Conference_Titel
Geoscience and Remote Sensing Symposium (IGARSS), 2010 IEEE International
Conference_Location
Honolulu, HI
ISSN
2153-6996
Print_ISBN
978-1-4244-9565-8
Electronic_ISBN
2153-6996
Type
conf
DOI
10.1109/IGARSS.2010.5651193
Filename
5651193
Link To Document