• DocumentCode
    3328786
  • Title

    Three-site study of variations introduced by standard site imperfections using the ANSI63.5-1988 standard site method for antenna calibration

  • Author

    Elliott, William M. ; Roman, John M. ; Robles, Ricardo

  • Author_Institution
    Paging Products Group, Motorola Inc., Boynton Beach, FL, USA
  • fYear
    195
  • fDate
    14-18 Aug 195
  • Firstpage
    327
  • Lastpage
    332
  • Abstract
    Current test methodology for performing FCC Part 15 radiated emissions measurements call for all antennas used in the measurements to be calibrated with “traceability to the NIST or equivalent standards organization”. Calibration per ANSI standard C63.5-1988 “meets the traceability requirement”. An antenna factor/site attenuation study was performed using seven broadband antennas at three EMC test sites to determine the overall deviations with respect to the current accepted error budget. Good agreement in the antenna factor and site attenuation data gives a strong indication that the error budget is acceptable. Furthermore, the excellent site to site agreement elevates the significance of errors in previously performed studies
  • Keywords
    ANSI standards; antenna testing; attenuation measurement; calibration; electromagnetic compatibility; electromagnetic interference; ANSI63.5-1988 standard site method; EMC test sites; FCC Part 15 radiated emissions measurements; NIST standards; antenna calibration; antenna factor; broadband antennas; error budget; site attenuation data; standard site imperfections; three-site study; traceability; Antenna measurements; Attenuation; Broadband antennas; Current measurement; FCC; Measurement standards; NIST; Performance evaluation; Standards organizations; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 1995. Symposium Record., 1995 IEEE International Symposium on
  • Conference_Location
    Atlanta, GA
  • Print_ISBN
    0-7803-3608-9
  • Type

    conf

  • DOI
    10.1109/ISEMC.1995.523574
  • Filename